You are required to read and agree to the below before accessing a full-text version of an article in the IDE article repository.
The full-text document you are about to access is subject to national and international copyright laws. In most cases (but not necessarily all) the consequence is that personal use is allowed given that the copyright owner is duly acknowledged and respected. All other use (typically) require an explicit permission (often in writing) by the copyright owner.
For the reports in this repository we specifically note that
- the use of articles under IEEE copyright is governed by the IEEE copyright policy (available at http://www.ieee.org/web/publications/rights/copyrightpolicy.html)
- the use of articles under ACM copyright is governed by the ACM copyright policy (available at http://www.acm.org/pubs/copyright_policy/)
- technical reports and other articles issued by M‰lardalen University is free for personal use. For other use, the explicit consent of the authors is required
- in other cases, please contact the copyright owner for detailed information
By accepting I agree to acknowledge and respect the rights of the copyright owner of the document I am about to access.
If you are in doubt, feel free to contact webmaster@ide.mdh.se
Functional reliability analysis of Safety Grade Decay Heat Removal System of Indian 500MWe PFBR
Publication Type:
Journal article
Venue:
Nuclear Engineering and Design
Abstract
Passive systemsare increasingly deployedinnuclear industry with an objective of increasing reliability and safety of operations with reduced cost. Methods for assessing the reliability of thermalhydraulic passive systems, that is systems with moving working fluid, address the issues in natural buoyancy-driven flow that could result in a failure to meet the design safety limits under accident scenarios. This is referred as design functional reliability. This paper presents the results of functional reliability analysis carried out for the passive Safety Grade Decay Heat Removal System (SGDHRS) of Indian Prototype Fast Breeder Reactor (PFBR). The analysis is carried out based on the overall approach reported in the Reliability Methods for Passive System (RMPS, European Commission) project. Functional failure probability is calculated using Monte-Carlo method and also with method of moments.
Bibtex
@article{Chandran1764,
author = {Senthil Kumar Chandran},
title = {Functional reliability analysis of Safety Grade Decay Heat Removal System of Indian 500MWe PFBR},
volume = {238},
pages = {2369--2376},
month = {February},
year = {2008},
journal = {Nuclear Engineering and Design},
publisher = {Elsevier},
url = {http://www.es.mdu.se/publications/1764-}
}